11
Battery Monitor
12.1V 0.0A 100%
DC Voltage
12.10V
Setup Alarms
[Press Enter]
4 Alarm relay
The VE.Net Battery Controller is equipped with a relay that can be programmed to signal alarms,
or when connected to a generator, to automatically start and stop a generator.
4.1 Where to find the “Setup Alarms”
Step 1.) Press “Enter” to enter the Battery Controller menu.
Step 2.) Press “▼” to scroll through the menu until you see “Setup Alarms”.
Note: If you can’t find the “Setup Alarms” menu, make sure that your VE.Net Panel is in
User and Install mode.
Step 3.) Press “Enter” to enter the “Setup Alarms” menu.
4.2 Alarm relay thresholds:
Setup Alarms
Model Default
Value
Range Step
size
Low Voltage The DC Voltage has to be below this
threshold to trigger the Low Voltage alarm.
12V/24V
48V
10.5V
42.0V
8-33
35-59
0.1
Low Voltage Clr The threshold that has to be reached again to
cancel an active Low Voltage alarm.
12V/24V
48V
10.5V
42.0V
8-33
35-59
0.1
Low Volt. Alarm Enables and disables the low voltage alarm.
Off on-off
High Voltage The DC Voltage has to be above this
threshold to trigger the High Voltage alarm.
12V/24V
48V
16V
58V
8-35
35-59
0.1
High Voltage Clr The threshold that has to be reached again to
cancel an active High Voltage alarm.
12V/24V
48V
16V
58V
8-35
35-59
0.1
High Volt. Alarm Enables and disables the high voltage alarm.
off on-off
Low SOC The low State of Charge threshold that will
activate the alarm.
80% 0-100 1
Low SOC Clr The State of Charge threshold that has to be
reached to cancel an active State of Charge
alarm.
80% 0-100 1
Low SOC Alarm Enables and disables the low SOC alarm.
off on-off
Note: Unlike other VE.Net devices, the VBC does not send its alarm status to the VPN.