Connections to ESP AC Breaker Panel - with two AC groups
0V from ESP System Panel
(allows System Panel to control backlight)
OR 0V from Boat supply
ESP AC Breaker Panel
9V from ESP System Panel
(allows System Panel to control backlight)
OR 9 - 30V from Boat supply
To high load 230V consumer (live)
To high load 230V consumer (neutral)
Inverter group Neutral Busbar
(not supplied)
20 A
16A
16A
10A
10A
10A
10A
10A
5A
5A
5A
WARNING:
The installer must ensure that the
rear of the panel and live bus bar
is inaccessible once installed.
Ensure all cables are correctly
sized for the fuse or circuit
breaker protecting them.
Inverter group
RCD
(not supplied)
High load
group RCD
(not supplied)
High load group Neutral Busbar
(not supplied)
To inverter load 230V consumer (live)
To inverter load 230V consumer (neutral)
WARNING:
Cut busbar
to separate
high load
and inverter
load groups.
A gap of at
least 5mm is
required.
Note:
Undo 2 x nuts to remove
backlight PCB to allow
fitting of Custom Window
Label
To 230V consumers (earth)
Earth Busbar (not supplied)
All supply & consumer earths to this point
ESP PANELS page 5